Abdomen MRI Dielectric Pad

High-dielectric MRI pad shaped for abdomen imaging, built to support B1 field uniformity without changing the scan protocol.

Size
115 × 34 cm
Material
High dielectric constant material
Evidence
1 cases
Abdomen MRI Dielectric Pad
MR workflow compatible
115 × 34 cm
1.5T / 3T
01 / Clinical evidence
With pad
Without pad
Without padWith pad

With vs. without pad

The page shows measured image pairs only where local clinical visuals exist.

Sequence
Abdominal MRI
Abdominal signal difference map
Difference map
Abdominal intensity profile comparison
Intensity profile
02 / Fit and workflow
Abdomen MRI Dielectric Pad placement on body

Placement

Anatomically shaped for the scan region, then used with the existing coil workflow.

Wrap the pad over the abdomen and secure it with the auxiliary belt so it remains stable during breathing.

01

Position

Place the pad directly on the target anatomy, conforming it to the body surface.

02

Insert into coil

Slide inside the standard flex or spine coil as usual. No hardware modification needed.

03

Scan

Run your existing protocol without any parameter changes. Improvement is immediate and passive.

Abdomen MRI Dielectric Pad rotating motion view
03 / Specifications
Width
115CM
Height
34CM
Sizes
Small · Medium · Large
Outer fabric
NEOPRENE POLYESTER 100%
Inner fabric
High dielectric constant material

Field strength

1.5T3T

Scanner compatibility

SiemensPhilipsGE

Clinical applications

Abdominal MRIDWIDCE imagingSignal dropout reduction

Common sequences

T2WDWIDCET1W FS
04 / Product notes

Features

Built around fit, passive signal support, and repeatable clinical handling.

Clinically proven improved MR images in all sizes (upper, medium, lower)

Provides clinically proven clear MRI (abdominal) images

Ergonomic design for better images

Improved anchorage with auxiliary belt

Frequently Asked Questions

No protocol changes are needed. Simply position the pad on the target anatomy and run your existing sequence without modification. The improvement in B1+ field homogeneity happens passively.

Yes. All MTechLab dielectric pads are MR Conditional and have been tested per ASTM F2503. They are safe for use in MRI systems at the field strengths listed on this page.

Yes. We regularly manufacture pads for non-standard anatomies, paediatric patients, and research applications. Contact us with the target circumference or dimensions and field strength — we'll specify the right configuration.

Wipe with a standard MRI-safe disinfectant (IPA wipe or equivalent). Do not autoclave or immerse in liquid. The outer fabric is resistant to common hospital disinfectants. Full reprocessing instructions are available on request.

3T systems show the largest absolute SNR gain because dielectric effects are strongest at higher frequencies. 1.5T also benefits significantly, particularly for deep anatomy. 7T research systems see the highest percentage improvement.

Use the following APA citation format when referencing this product in a publication or clinical report:

MTechLab. (2026). Abdomen MRI Dielectric Pad [MRI Dielectric Pad]. MTechLab. https://mtechlab.com/solutions/mri-pads/abdomen

Trial request

Send your scanner, field strength, and anatomy. MTechLab can recommend the right pad.