Latest
CES 2026/Strategic MOUs signed at CES 2026 Las Vegas — ARVIVA Therapeutics, Korea Lighting & Morla Moves.
1 / 4
ENG/KOR
Contact

MTechLab

Solutions · MRI PadsHead

Head MRI Dielectric Pad

High-dielectric MRI pad shaped for head imaging, built to support B1 field uniformity without changing the scan protocol.

Size
57 cm circ. · 24 cm neck
Material
High dielectric constant material
Evidence
3 cases
Head MRI Dielectric Pad
MR workflow compatible
57 cm circ. · 24 cm neck
1.5T / 3T
01 / Clinical evidence
With pad
Without pad
Without padWith pad

With vs. without pad

The page shows measured image pairs only where local clinical visuals exist.

Sequence
7T DTI b0 1.2 mm
02 / Fit and workflow
Head MRI Dielectric Pad placement on body

Placement

Anatomically shaped for the scan region, then used with the existing coil workflow.

Wrap around the head and align the face opening before positioning inside the head coil.

01

Position

Place the pad directly on the target anatomy, conforming it to the body surface.

02

Insert into coil

Slide inside the standard flex or spine coil as usual. No hardware modification needed.

03

Scan

Run your existing protocol without any parameter changes. Improvement is immediate and passive.

Head MRI Dielectric Pad rotating motion view
03 / Specifications
Circumference
57CM
Neck circumference
24CM
Sizes
Small · Medium · Large
Outer fabric
NEOPRENE POLYESTER 100%
Inner fabric
High dielectric constant material

Field strength

1.5T3T

Scanner compatibility

SiemensPhilipsGE

Clinical applications

Brain MRIHigh-field neuroimagingSignal uniformity supportResearch protocols

Common sequences

FLAIRT1WDWIDTI
04 / Product notes

Features

Built around fit, passive signal support, and repeatable clinical handling.

High dielectric constant material contributes to B1 field homogenization

Provides clinically proven clear MRI brain images

Ergonomic design for better images

Harmless material to the human body

Frequently Asked Questions

No protocol changes are needed. Simply position the pad on the target anatomy and run your existing sequence without modification. The improvement in B1+ field homogeneity happens passively.

Yes. All MTechLab dielectric pads are MR Conditional and have been tested per ASTM F2503. They are safe for use in MRI systems at the field strengths listed on this page.

Yes. We regularly manufacture pads for non-standard anatomies, paediatric patients, and research applications. Contact us with the target circumference or dimensions and field strength — we'll specify the right configuration.

Wipe with a standard MRI-safe disinfectant (IPA wipe or equivalent). Do not autoclave or immerse in liquid. The outer fabric is resistant to common hospital disinfectants. Full reprocessing instructions are available on request.

3T systems show the largest absolute SNR gain because dielectric effects are strongest at higher frequencies. 1.5T also benefits significantly, particularly for deep anatomy. 7T research systems see the highest percentage improvement.

Use the following APA citation format when referencing this product in a publication or clinical report:

MTechLab. (2026). Head MRI Dielectric Pad [MRI Dielectric Pad]. MTechLab. https://mtechlab.com/solutions/mri-pads/head

Trial request

Send your scanner, field strength, and anatomy. MTechLab can recommend the right pad.