Anatomy pad
Breast Pad · MTL-A-B1
Shaped for one region, so its inserts sit where that anatomy needs them.
A wearable high-permittivity pad for breast MRI, intended to improve B₁ field homogeneity within the RF coil. Supplied as a set with three auxiliary pads and an aluminium carrying case.

Operating principle
At high field strengths the RF wavelength in tissue shortens, and interference and attenuation leave parts of the anatomy with a weaker B₁⁺ field. The pad’s barium-titanate-based medium interacts passively with the RF field and redistributes it locally, toward the anatomy the pad covers. It needs no power, no cables and no change to the scan protocol.

Set contents
A high-permittivity pad acts locally, on the anatomy it lies against, so it has to fit closely. Because anatomy differs from patient to patient, every pad is supplied as a set: the anatomy pad, three auxiliary pads that close gaps and extend coverage, and an aluminium carrying case.

Breast Pad · MTL-A-B1
Shaped for one region, so its inserts sit where that anatomy needs them.



MTL-A-G1, G2 and G3
Flat pads with the same high-permittivity inserts and CDP airprene cover, in three widths.

The set is supplied in a hard aluminium case with a carrying handle, marked with the product name and the MTechLab logo.

| Model | Sections | Size W × D × T | Weight | Insert |
|---|---|---|---|---|
| MTL-A-G1 | 1 | 96 × 176 × 8 mm | 210 g | 80 × 160 × 3 mm |
| MTL-A-G2 | 2 | 183 × 176 × 8 mm | 420 g | 160 × 160 × 3 mm |
| MTL-A-G3 | 3 | 270 × 176 × 8 mm | 630 g | 240 × 160 × 3 mm |
Fitting
Wraps the chest, with shaped cups that follow the breast, and closes with hook-and-loop.
Before use Check the cover, inserts and closure; do not use a damaged pad. Make sure the pad suits the region to be scanned.

Step 1: Centre the pad on the middle of the chest.

Step 2: With the arms raised, wrap the pad close round the body.

Step 3: Close the hook-and-loop to secure it.
Then position the patient in the RF coil and scan with your existing protocol. The pad works passively and needs no change to sequence parameters. Before the first examination, check outside the scanner that the anatomy fits inside the RF coil with every pad to be used. Each auxiliary pad is 8 mm thick.
Construction
High-permittivity inserts improve B₁ field homogeneity around the chest
Thirty-two inserts arranged around the chest
Shaped cups follow the anatomy
Closes with non-magnetic hook-and-loop
Specifications
Dimensions and weight are nominal values. Dielectric properties are those of the insert medium.
Questions
Evaluation
Tell us your MRI system, field strength and target anatomy. We will recommend a set and arrange an evaluation.